德国wolf怎么补水Designed for anterior and posterior eye segments

新闻资讯2026-04-21 10:12:36

公司简介

A.R.C公司成立于1996年,总部位于德国纽伦堡,是全球著名的专注于医用领域激光器研发、生产、应用的公司。曾在纳秒级Nd:YAG激光器治疗白内障、准分子激光器用于视力矫正等领域开创了里程碑,是目前全球最强大的医用激光公司之一。产品包括多种CO2激光器、半导体激光器、绿光/脉冲/Q开关固体激光器。

产品列表

CO2 Laser

德国wolf怎么补水Designed for anterior and posterior eye segments_https://www.jmylbn.com_新闻资讯_第1张

Treatments with CO2 laser are characterized by a very successful healing process – there remain often no scars after treatments on the surface. By the wrinkle removal, skin resurfacing and streamlining takes place.

 

Less pain and fast cure with the C-Las

This carbon dioxide laser is an approved tool for an extremely fine cutting and removal of the histoid. The CO2 laser is securely established in all the specialist disciplines since many years. It is very welcome by many doctors in hospitals as well as in many outpatient clinics thanks to its reliability and versatility.
C-Las is flexible

 

Fast regeneration

High flexibility – simple in use and more possibilities with the Waveguide system.  The output power of  up to 25 watt and a big range of motion are the features of the CO2 fiber.
C-Las is an allrounder

 

Micromanipulator

The Micromanipulator can be adapted to almost all the microscopes of your choice.
C-Las is innovative

 

Fiber or articulated arm?

The desicion depends on your needs. The waveguide technology allows a very flexible application of a laser with a high mobility level. The option with an articulated arm for colposcopy and micromanipulators.

德国wolf怎么补水Designed for anterior and posterior eye segments_https://www.jmylbn.com_新闻资讯_第2张

C-Las has two versions for different types of application


Simply good results

The latest technology which is represented in our Co2 laser allows a compact design. The location of the laser doesn´t matter, on the table or on the trolley, the C-Las suits in every surgery room.This design shows a strong character.
C-Las is precise 

Technical data:

Wavelength- 
output power *
10600 nm Output power min. 25 watt with waveguide min. 30 watt with articulated arm Operating mode quasi Gauss with waveguide Pulslength, adjustable CW and pulsed Beam guidance flexible waveguide / articulated arm Accessories universal handpiece/ scanner/ micromanipulator Weight 18 kg ready-to-operate Dimensions 491 x 478 x 200mm Power supply 100-260 V,50/60 Hz, 10A

Diode Laser

德国wolf怎么补水Designed for anterior and posterior eye segments_https://www.jmylbn.com_新闻资讯_第3张

Flexible - Versatile - User-friendly

The Laser-System with a variable penetration depth. Apply your laser beam in 2 different wavelength or a mixture from both. This means a high grade of flexibility for you as a surgeon and maximum Comfort for your patients.

Two laser beams through one fiber

The best from two worlds
… best in coagulation
… best in cutting

 

Hybrid 980 + 532 nm

  • One Handpiece - two laser beams

  • High Power IR 980 is brought together
    with a wavelength of 532 nm

  • Touch-Screen for both lasers

  • Elegant Design

  • Benefit from a broad range of 
    affordable accessories from A.R.C.

德国wolf怎么补水Designed for anterior and posterior eye segments_https://www.jmylbn.com_新闻资讯_第4张

 
The 980 nm wavelength offers precise cutting and protects the surrounding tissue. Postoperative pain is significantly reduced when compared to non laser procedures. Benefit from minimal or no requirement for anesthetics.
The system creates short pulses for minimal discomfort and improved patient compliance.

德国wolf怎么补水Designed for anterior and posterior eye segments_https://www.jmylbn.com_新闻资讯_第5张

 
532 nm is an established wavelength for a wide range of soft tissue applications.  The depth of penetration is limited for increased control while providing excellent hemostasis, vaporization and cutting power. This allows a more tolerable procedure and - whenever possible - convenience for the patient.
The superficial penetration of the 532 nm wavelength minimizes complications and offers modern treatment options.
Its incorporated selective ablation avoids epithelial damage.

德国wolf怎么补水Designed for anterior and posterior eye segments_https://www.jmylbn.com_新闻资讯_第6张

The FOX from the A.R.C. Laser is the only calibrateable laser worldwide. No other system has such an advantage. FOX laser is the only one which can reliably provide you with the adjusted output power.
FOX sets new standards in security.

Training videos directly on the display

Training videos can be saved on the USB stick, which is part of the standard delivery of FOX. The videos come up on the display as soon as you choose it in the menu.
FOX is innovative

Green aiming beam

The green aiming beam of FOX laser improves the alignment and the exact sighting during the treatment.
FOX gives you a better view

Touch screen

The modern color touch screen with a very simple guide: you can set and change the adjustments intuitionally.

Mobile like your assistant

The convenient battery operation allows implementing treatments everywhere and every time. You can transport the FOX in the helpful case to every place you need.
FOX means flexibility

德国wolf怎么补水Designed for anterior and posterior eye segments_https://www.jmylbn.com_新闻资讯_第7张

Technical data:

Wavelength – Output power* 810 nm: 8 watt 940 nm: 4 watt 980 nm: 12 watt 1064 nm: 10 watt Puls length, adjustable 0,1 ms to cw Puls interval 0,1 ms to cw Aiming beam green 532 nm, < 1 mW Dimensions 142 x 163 x 174 mm Weight  1,2 kg operational Power supply 220 V or battery driven

德国wolf怎么补水Designed for anterior and posterior eye segments_https://www.jmylbn.com_新闻资讯_第8张

The Wolf - optional with 980, 1064 or 1470 nm - has a potential for very big amount of applications. The laser is designed for giving up to 18 watt output power.

Wins through qualitiy, design and art of processing.

All-rounder

This laser system provides the latest laser technology, which can be for example very useful at treatments with 1470 nm in endovascular surgery thanks to the latest donut fiber. The laser provides you with 18 watt in the version of 980 nm: it is ideal for surgical, orthopedic, dermatological or ENT treatments.
Wolf is innovative

Modern design

The Wolf rises over the competitors thanks to its features. We were able to reduce the dimensions and improve the handling due to using of long-lasting and reliable materials. It provides flexibility at the installation in clinics or surgery rooms.
Wolf is stackable 

The best in its class

We offer advanced performance index in form, size and function on the basis of the Wolf housing. Thanks to its range of fibers from 200 to 600 µm and different handpieces, wolf allows you flexibility and versatility, which perfectly suits in every modern doctor’s office. 
Wolf is space-saving

Easy in application

  • Color touch screen

  • Editable applications

  • Individual programming

  • Different fibersizes and applicators available

  • Plug & Play

Wolf is modern

德国wolf怎么补水Designed for anterior and posterior eye segments_https://www.jmylbn.com_新闻资讯_第9张

Technical data:

Wavelength laser 980 nm 1064 nm 1470 nm Display / Control color touch screen color touch screen color touch screen Output Power (Laser) 18 W 10 W 8 W Aiming Beam 532 nm, ajdustable 532 nm, adjustable 532 nm, adjustable Fiber coupling A.R.C. Laser A.R.C. Laser A.R.C. Laser Treatment mode CW, pulsed CW, pulsed CW, pulsed Power requirements 19 V, 4,7 A 19 V, 4,7 A 19 V, 4,7 A Dimensions 10 x 24 x 20 (cm) 10 x 24 x 20 (cm) 10 x 24 x 20 (cm) Weight 2,8 Kg 2,8 Kg 2,8 Kg

Frequency doubled Nd:YAG / KTP -Laser

德国wolf怎么补水Designed for anterior and posterior eye segments_https://www.jmylbn.com_新闻资讯_第10张

The Nuvolas offers the whole 8 Watt output power on laser end. This powerful KTP laser guarantees more power than even needed to run the most diverse treatments. Nuvolas is one of the most powerful lasers for medical applications.

More power  - more possibilities

 

Wide application spectrum

The green laser can be applied in different fields of medicine.
Nuvolas means green

A unique technical standard

  • 8 Watt output power on laser end

  • Weight is just 23 kg

  • Removable display control

  • Easy usage

  • Different adjustments

  • Different handpieces and applications

Nuvolas is user friendly

The easy click connector does not require any turning of screws after it is in place. Click in- and it fits. The fibers are attractively priced, due to the plastic connector. Fibers are available in different sizes up to 600 µm.

Technical data:

Display / Control color touch screen Output Power (Laser) 8 W Aiming Beam 635 nm, adjustable Fiber Connection A.R.C. Laser Operating Modes CW, pulsed Cooling forced air Power Requirements 110 - 230 V / 50-60 Hz - 10 A Dimensions (HxWxD) 478 x 200 x 491mm Weight (without case) 23 Kg

Ophthalmic Systems

德国wolf怎么补水Designed for anterior and posterior eye segments_https://www.jmylbn.com_新闻资讯_第11张

redesigned from scratch: SLT Laser CITO 532

Modern technology "Made in Germany" redefines the SLT-Treatment. 
Convincing technical refinements characterize this unique laser system on which we are proud: No heating on the housing and no UV light at the cavity. The life time of the CITO 532 is theoretically unlimited – stable and without loosing energy throughout the entire lifecycle.

Briefly: 2 years of research and development can be seen. An investment that is not at leastbeneficial for your patients.

SLT is a laser therapy which may replace medication for the treatment of open-angle glaucoma (OAG). Laser Selected Trabeculotomy is a gentle and repeatable laser treatment. It promotes cellular regeneration of trabecular meshwork without any medication.

 

CITO 532: no compromises.

  • Designed for the anterior segment

  • Highest repetition rate thanks to our Rapid Procedure Rapid-Trigger-Mode (RTM)

  • Optional head-up-display

  • No high voltage inside - No UV-light on the cavity

  • < 2% Deviation: Highest pulse-to-pulse stability for REPRODUCIBLE RESULTS

Unique innovations are the Rapid-Trigger-Mode (RTM) for a fast repetition rate and the optional head-up-display: the selected treatment power is always in view.

World leading technology for Ophthalmology

PCL5
Specially coated optics with parallel or convergent tube provide a detailed view into the anterior segment

Die SLT ist a natural way to reduce IOP by stimulating the Trabecular Meshwork with its specific "low level laser beam"

德国wolf怎么补水Designed for anterior and posterior eye segments_https://www.jmylbn.com_新闻资讯_第12张

德国wolf怎么补水Designed for anterior and posterior eye segments_https://www.jmylbn.com_新闻资讯_第13张

Slit lamp PCL5

Benefit from specially coated optics with parallel or optionally a convergent tube which provides a detailed view into the anterior segment.

Head-up Display
Check all the necessary values at a glance - without taking the eyes from the eyepiece. The display follows each alteration of the energy level. The overall input energy is displayed in addition.

 

The CITO 532 without compromises.  Redesigned from scratch by A.R.C. Laser.  

specifications:

energy 0.2 to2.0 mJ, quasi continuous spot diameter 400 μm in aiming beam focus repetition rate, pulse > 10 Hz pulse width 3 ns aiming beam rote Diode 635 nm / 1 mW, variable laser protection filter permanent treatment angle 3,2° Laser path inside the housing arrangement of laser source central with the microscope weight 53 kg with slit lamp space needed 0.5 m2 power requirements 100 bis 240V 50/60 Hz, 600 Watt laser class 3b | 532 nm, E = 2,5 mJ
aiming beam: 635 nm, P < 5 mW

Alterations of the described features or pictured features are possible. Please keep updated on the current status before ordering.

subject to change without notice. © A.R.C. Laser 2016.

Classic + PCL5 ZL

  • Classical design - illumination beam path over prism

  • LED or halogen illumination

  • Single hand operation

  • Compact design

  • In combination with Nd:YAG Laser

The Classic is compatible

Classic + PCL5 SHL

  • Illumination from above

  • Top notch optical quality

  • Coaxility of illumination / laser beam / monitoring optic

The Classic is modern

Technical data:

Output power 1,5 W at fiber end Pulse length 10 ms - cw Pulse pause 100 ms - 1.000 ms Repeat frequency 1 to 9 Hz Laser beam  635 nm, < 1 mW Utility space 250 x 190 x 52 mm Weight 3,3 kg - complete Supply connection  rechargeable battery  / 90 - 230 VAC Laser outputs  2 fiber ports  Accessories indirect ophthalmoscope / endo probes

德国wolf怎么补水Designed for anterior and posterior eye segments_https://www.jmylbn.com_新闻资讯_第14张

The FOX from A.R.C. Laser is worldwide the only laser that can be calibrated. No other system has this advantage. Only the mobile FOX Laser offers you reliably the setted output power.

FOX sets standards in safety

 

Training videos directly on the display

Trainings and schooling videos can be stored onto the supplied memory stick from A.R.C. Laser. The videos are shown on the display, as soon as you select the data from the menu.
FOX is innovative

Green laser beam

The green laser of the FOX laser improves the orientation and the exact aiming during course of treatment.
FOX is easily readable

Touch-Screen

The modern color touch display with an easy user handling: changing and customizing settings intuitively.
FOX is intuitive to use

Mobile like your assistant

The comfortable battery use allows a laser treatment any time any place. With the handy transport case you can take your FOX everywhere you like.
FOX stands for flexibility

德国wolf怎么补水Designed for anterior and posterior eye segments_https://www.jmylbn.com_新闻资讯_第15张

Technical data:

Wavelength – output power * 810 nm: 8 Watt 940 nm: 4 Watt 980 nm: 12 Watt 1064 nm: 10 Watt Pulse length, adjustable 0,1 ms to cw Pulse interval 0,1 ms to cw Laser beam green 532 nm, < 1 mW Measurements BWH 142 x 163 x 174 cm Weight 1,2 kg operational Power built-in rechargeable battery

德国wolf怎么补水Designed for anterior and posterior eye segments_https://www.jmylbn.com_新闻资讯_第16张

The Q-Las gives you the possibility to treat secondary cataract and the wide-angle-glaucoma. It links economy, ergonomics, and longevity in a very innovative way.

  • Outstanding focusing with the three part laser beam

  • Combination with Trabeculas / Classic

  • Laser beam and slit illumination are coaxial

 

The superior concept

The dynamic focus from A.R.C. Laser supports you effectively. The unique Tristar Focus is trend-setting. With only just one laser spot you can calmly trigger the laser. We call that intelligent laser technology.

The Q-Las can be combined with the Classic retina laser and the glaucoma laser Trabeculas. Furthermore is the Q-Las Laser available with 2 different slit lamp types.

Q-Las + PCL5 ZL

  • With a classical YAG slit lamp

  • Illumination radiation channel through prism

Q-Las + PCL5 SHL

  • Light source at the tip of the slit projector

  • High end optical quality

Technical data:

Pulse length  < 4 ns Aiming beam diode red / 3 beam Outout 0,3 - 10 mJ, smooth spot  Size diameter in the air  < 10 µm Angel, laser lens 16° Burst mode  1 - 2 - 3 pulse, 20 µs pulse pause Repeat frequency 2,5 5 pulses per second Mode structur gauß Focus shift 2 stepped - 125/250 µ - posterior Cooling air Input tension  230 V, 50 Hz, 3A / 110 V, 6 A

德国wolf怎么补水Designed for anterior and posterior eye segments_https://www.jmylbn.com_新闻资讯_第17张

Cataract surgery becomes 100% laser-surgery with the CETUS.

The Nano-Laser can be operated with a femto laser to do the rhexis, or without the expensive femto laser. In either case, you benefit by performing full laser cataract surgery. 

The A.R.C. Nano-Laser is very compact meaning it needs only a fraction of a Femto‘s space.

 

Upgrade your Phaco with a laser system as easy as 1-2-3

德国wolf怎么补水Designed for anterior and posterior eye segments_https://www.jmylbn.com_新闻资讯_第18张

Nano-Laser ist gentle, safe and easy to use

No more expensive hand pieces.
No more cross contamination.
No more need for a Femto.

With the introduction of Lasik, laser became the number one tool in ophthalmology and patient satisfaction.

 

The A.R.C. Nano-Laser emulsifies the cataract with pulses that are gentle and effective.

Inexpensive, single-use, lightweight laser hand piece eliminates the need for cleaning, sterilization and tuning of the heavy phaco hand piece.  

Coaxial with two different sleeves allows small incisions of 2.2 or 2.6 mm.
Your other hand assists with your manipulator. Coaxial fluid management works the same way as conventional ultrasound phaco.

The Nano-Laser surgery benefits from an extremely little energy into the eye.

德国wolf怎么补水Designed for anterior and posterior eye segments_https://www.jmylbn.com_新闻资讯_第19张

Specifications

Operating mode pulsed Shot frequency up to 10Hz Wavelength 1064nm Pulse energy 3mJ to 10mJ Pulse length 5ns Control 7“ TouchScreen Power requirements

110-240Vac, 650VA, 50 to 60Hz

Dimensions 135*478*421mm (device housing) Weight 12kg

德国wolf怎么补水Designed for anterior and posterior eye segments_https://www.jmylbn.com_新闻资讯_第20张

This is how we understand a combined system. Usually one has the idea to join all lasers in one housing. We think that our crossover from diagnostic and treatment for the anterior and posterior eye segment is propably the one with the most advantages.

Our solution is called VARIO:

 

You need a YAG Laser and a Laser for Photocoagulation and a laser to perform SLT?

  • Designed for the anterior and posterior segment

  • Modern Laser systems on one table

  • Optional head-up-display

  • Spacious legroom for wheelchair patients

World leading technology for Ophthalmology

 

PCL5
Specially coated optics with parallel or convergent tube provide a detailed view into the anterior segment or the posterior segment.

德国wolf怎么补水Designed for anterior and posterior eye segments_https://www.jmylbn.com_新闻资讯_第21张

德国wolf怎么补水Designed for anterior and posterior eye segments_https://www.jmylbn.com_新闻资讯_第22张 

德国wolf怎么补水Designed for anterior and posterior eye segments_https://www.jmylbn.com_新闻资讯_第23张

Slit lamp PCL5 
Benefit from specially coated optics with parallel or optionally a convergent tube which provides a detailed view into the anterior segment.

Head-up Display
Check all the necessary values at a glance - without taking the eyes from the eyepiece. The display follows each alteration of the energy level. The overall input energy is displayed in addition.

 

Combine your lasers - get the best out of the available space

德国wolf怎么补水Designed for anterior and posterior eye segments_https://www.jmylbn.com_新闻资讯_第24张

A.R.C. Slit lamps convince with brillant looks and highest quality. Made in Germany

The PCL5 is slitlamp that is a precision instrument for reliable diagnosis  for your practice. A premium product where you can count on. High user comfort paired with brilliant stereoscopic lenses for a large depth of focus and impressing color fidelity – ideal for the posterior and anterior eye section.

  • The slit (high light yield) is easily adjustable with the hand

  • IR-& UV filters are standard

  • 5-times magnification

  • Change from LED to Halogen in you practice

PCL5 SHD is diagnosis for a faire price

德国wolf怎么补水Designed for anterior and posterior eye segments_https://www.jmylbn.com_新闻资讯_第25张

Technical data:

PCL5 SHD

Gap height 0,5 - 8 mm continuous Circle of light fields 0.2, 1, 2, 3, 4, 6, 8 mm Test mark with fixation Gap rotation ± 90° (0-180°) Adjustment of lighting horizontally ± 90° Filter blue, red-free (green), gray (10%).
UV and heat filters are integrated
Lighting halogen 6 V, 20 W 
0 lux bis 600,000 lux (Halogen)
optional: LED 14 V, 5 W Eye protection filter optional Electrical connection values 110 V - 240 V 50/60 Hz Weight 12.7 kg
Stereo angle 10° Adjustable eyepieces ± 8 dpt Amplifications 6.3x / 10x / 16x / 25x / 40x Eyepiece 12,5x PD 52 to 78 mm Pivoting of the microscope axis horizontal ± 30°

PCL5 ZD

Gap height 1 - 16 mm continuous Circle of light fields Ø: 1 mm test brand Gap rotation ± 90° (0-180°) Adjustability of the
lighting
horizontally ± 90° Filter blue, red-free (green), gray (10%).
UV and heat filters are integrated
Lighting halogen 6 V, 20 W 
0 lux bis 600,000 lux (Halogen)
optional: LED 14 V, 5 W Eye protection filter optional Electrical connection values 110 V - 240 V 50/60 Hz Weight 12.7 kg

Consumables

德国wolf怎么补水Designed for anterior and posterior eye segments_https://www.jmylbn.com_新闻资讯_第26张

More than 75% of adults suffer from periodontitis (PD) and other bacterial infections of the gums or the oral cavity. Attempts to mechanically clean the bleeding gums may lead to the transfer of bacteria in the mouth into the bloodstream (bacteremia) potentially causing the bacteria to spread throughout the body.

The consequence: Unwanted bacteria may result in cerebrovascual diseases. 
Due to the stress on the immune system, the risk of diseases of the arteria carotis, heart attacks, arthritis, diabetes and premature births is rising. This clearly shows that the PD bacteria is more harmful than smoking, obesity or high cholesterol levels.

Now, it is possible to reduce or totally avoid the use of antibiotics and eliminate all of the associated health risks for patients with periodontitis. Independent of antibiotic resistance, EmunDo® selectively destroys the relevant PD-Germs.

EmunDo® Therapy reaches germs  even in deep gingival pockets. Patients that undergo an extensive, repeated mechanical cleaning now have the chance to lose less root substance. Your patients will appreciate  the lower hypersensitivity.

EmunDo & FOX III - Flyer (PDF)